Design and Study of a Nanocavity-based One-dimensional Photonic Crystal for Potential Applications in Refractive Index Sensing

Sediq, Khalid N. and Muhammadsharif, Fahmi F. and Ramadan, Simko O and Sedeeq, Shalaw Z. (2023) Design and Study of a Nanocavity-based One-dimensional Photonic Crystal for Potential Applications in Refractive Index Sensing. ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY, 11 (2). pp. 95-98. ISSN 2410-9355

[img] Text (Research Article)
ARO.11298.VOL11.NO2.2023.ISSUE21-PP95-98.pdf - Published Version
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (1MB)
Official URL: http://dx.doi.org/10.14500/aro.11298

Abstract

Refractive index (RI) can be used to identify a particular substance and determine its purity and concentration. The RI of glucose solution with various concentrations can be determined using a distributed Bragg reflective (DBR) device containing a nanocavity. The optical property of the reflection spectrum produced by DBR is sensitive to the variation of the refractive index. In this study, a DBR with a cavity width of 220 nm, located in the middle of the device, is designed and used to sense the variation in the refractive index of glucose at different concentrations. The proposed design showed a sharp dip pattern within the reflection spectrum. The wavelength of the absorption peak was found to be sensitive to trivial variations in the refractive index of glucose solution. Results showed that the variation in the refractive index of glucose within the order of Δn = 0.02 has led to a noticeable shift in the absorption spectrum by Δλ = 2.6 nm. Furthermore, the sensitivity of the proposed device was found to be 130 nm/RIU which is considered high compared with those reported in the literature. Hence, the proposed structure can be a promising optical device for chemical ultrasensing applications.

Item Type: Article
Additional Information: Belay, A., 2018. Concentration, wavelength and temperature dependent refractive index of sugar solutions and methods of determination contents of sugar in soft drink beverages using laser lights. Journal of Lasers, Optics and Photonics, 5, p.187. Elblbesy, M.A., 2020. The refractive index of human blood measured at the visible spectral region by single-fiber reflectance spectroscopy. AIMS Biophys, 8, pp.57-65. DOI: https://doi.org/10.3934/biophy.2021004 Harrill, R., 1994. Using a Refractometer to Test the Quality of Fruits and Vegetables. Pine Knoll, California. Kumar, S., and Das, R., 2018. Refractive index sensing using a light trapping cavity: A theoretical study. Journal of Applied Physics, 123, p.233103. DOI: https://doi.org/10.1063/1.5029233 Leem, J.W., and Yu, J.S., 2013. Design and fabrication of amorphous germanium thin film-based single-material distributed Bragg reflectors operating near 2.2 μm for long wavelength applications. Journal of the Optical Society of America B: Optical Physics, 30, pp.838-842. DOI: https://doi.org/10.1364/JOSAB.30.000838 Lin, J.Y., and Su, D.C., 2003. A new method for measuring the chiral parameter and the average refractive index of a chiral liquid. Optics Communications, 218, pp.317-323. DOI: https://doi.org/10.1016/S0030-4018(03)01183-0 Mohammed, Z.H., 2019. The fresnel coefficient of thin film multilayer using transfer matrix method TMM. IOP Conference Series: Materials Science and Engineering, 518, p.032026. DOI: https://doi.org/10.1088/1757-899X/518/3/032026 Reis, J.C.R., Lampreia, I.M.S., Santos, A.F.S., Moita, M.L.C., and Douhéret, G., 2010. Refractive index of liquid mixtures: Theory and experiment. ChemPhysChem, 11, pp.3722-3733. DOI: https://doi.org/10.1002/cphc.201000566 Shaban, M., Ahmed, A.M., Abdel-Rahman, E., and Hamdy, H., 2017. Tunability and sensing properties of plasmonic/1D photonic crystal. Scientific Reports, 7, p.41983. DOI: https://doi.org/10.1038/srep41983 Shanmugan, V., Shah, M., Teo, S., and Ramam, A., 2004. Dielectric-based Distributed Bragg Reflector (DBR) Mirrors for Tunable MOEMS Applications. In: Proceedings of SPIE-the International Society for Optical Engineering, p.5641. DOI: https://doi.org/10.1117/12.572816 Shi, Q.G., Ying, L.N., Wang, L., Peng, B.J., and Ying, C.F., 2014. A method of the detection of marine pollution based on the measurement of refractive index. Applied Mechanics and Materials, 551, pp.347-352. DOI: https://doi.org/10.4028/www.scientific.net/AMM.551.347 Singh, V.K., Jaswal, B.B.S., Kumar, V., Prakash, R., and Rai, P., 2013. Application of he-ne laser to study of the variation of refractive index of liquid solutions with the concentration. Journal of Integrated Science and Technology, 1, pp.13-18. Tan, C.Y., and Huang, Y.X., 2015. Dependence of refractive index on concentration and temperature in electrolyte solution, polar solution, nonpolar solution, and protein solution. Journal of Chemical and Engineering Data, 60, pp.2827-2833. DOI: https://doi.org/10.1021/acs.jced.5b00018 White, I.M., and Fan, X., 2008. On the performance quantification of resonant refractive index sensors. Optics Express, 16, pp.1020-1028. DOI: https://doi.org/10.1364/OE.16.001020 Yeh, Y.L., 2008. Real-time measurement of glucose concentration and average refractive index using a laser interferometer. Optics and Lasers in Engineering, 64, pp.666-670. DOI: https://doi.org/10.1016/j.optlaseng.2008.04.008 Zaky, Z.A., Alamri, S., Zhaketov, V.D., and Aly, A.H., 2022. Refractive index sensor with magnified resonant signal. Scientific Reports, 12, p.13777. DOI: https://doi.org/10.1038/s41598-022-17676-0
Uncontrolled Keywords: Distributed Bragg Reflectors, Photonic crystal, Nanocavity, Refractive index, Sensor
Subjects: Q Science > QC Physics
Divisions: ARO-The Scientific Journal of Koya University > VOL 11, NO 2 (2023)
Depositing User: Dr Salah Ismaeel Yahya
Date Deposited: 16 Oct 2023 08:00
Last Modified: 16 Oct 2023 08:00
URI: http://eprints.koyauniversity.org/id/eprint/414

Actions (login required)

View Item View Item